Resonance R140 Portable OAE Hearing Screener
GENERAL SPECIFICATIONS
DIMENSIONS AND WEIGHT
- L x W x H: 180 x 135 x 41 mm
- Net weight: 450 g
- Case: ABS
DISPLAY
- 7” TFT resistive touch screen display
- 800 by 480 resolution at 133 pixels per inch (ppi) 262K colors
DATA TRANSFER
- Bluetooth 2.1
COMMUNICATION PORT
- No. 1 USB slave
- No. 1 USB Host (pen drive connection for software upgrading)
POWER
POWER SUPPLY
- Built-in 3.6 V/3.1 Ah rechargeable lithium-ion battery
- External Medical power supply/charger: Input 100 – 240 V ac / 0.3 A – 50/60 Hz; Output +5 V dc / 2 A
BATTERY LIFE RECHARGEABLE BATTERY
- Up to 3 hours of continuous testing
- Charge time with external medical power supply: 80% in 2 hours. Charging cradle provided as a standard.
ENVIRONMENTAL CONDITIONS
OPERATING ENVIRONMENT
- Storage temperature: from -20 to +50°C
- Operating temperature: from +15 to +35°C
- Humidity: up to 90%, (non-condensing)
- Ambient pressure: from 700 hPa to 1060 hPa
COMPLIANCE/REGULATORY STANDARDS
Designed, tested and manufactured to meet the following European and International Standards:
- EN 60645-6
- Safety: EN 60601-1
- EMC: EN 60601-1-2
TEOAE
SAMPLE RATE
- 24 bit 44,1ksps
STIMULUS LEVEL
- 70 – 90 dB pe SPL
STIMULUS RATE
- 66 Hz
WINDOW OF ANALYSIS
- 512 samples (3 – 15 ms)
TEST TIME
- 500 to 1250 stimuli (from 30 to 75 s)
STIMULATION PROTOCOL
- non-linear click
ACQUISITION BANDWIDTH
- from 750 Hz to 5 kHz
ARTEFACT LEVEL
- from 20 to 60 dB SPL
TEOAE SCREENING
RESPONSE DETECTION
- Statistical analysis of signal polarity
PROTOCOLS
- 3 user definable
TEOAE DIAGNOSTIC
RESPONSE DETECTION
- User defined stop criterion SNR 3, 6 or 9 dB, in minimum 2 and maximum 5 of the 5 available frequency bands.
FREQUENCY BANDS
- 1, 1.5, 2, 3, 4 kHz
PROTOCOLS
- 3 user definable
DPOAE
FREQUENCY RATIO F2/F1
- 1,22
F2 FREQUENCIES
- 1.5 – 12 kHz, user definable from 2 to 15
L2 STIMULUS LEVEL
- 30 – 70 dB SPL
L1 STIMULUS LEVEL
- User definable: automatic (L1=0,4*L2+39 dB), L1=L2, L1=L2+10 dB
ARTEFACT LEVEL
- from 0 to 40 dB SPL
FREQUENCY RESPONSE DETECTION
- User defined stop criterion SNR 3, 6 or 9 dB for each frequency
RESPONSE DETECTION
- From 2 to the number of enabled frequencies
FREQUENCY TEST TIME
- Customisable by User from 2 to 16 s
PROTOCOLS
- 2 pre-set (70dB e 65-55dB), 3 user definable
MEASUREMENT TYPES
Screening and Diagnostic Testing
TEOAE
- 0.7 to 5 kHz, Stimulus 70-90 dB pe SPL
DPOAE
- 1.5 to 12 kHz, 30 to 70 dB SPL
PROBE
- Connector: LEMO push-pull, circular
- Description: Integrated microphone and receivers in probe head and Calibration data stored in the probe
- Cable length: 130 cm
- Weight: 5 g
- Ear tips: Disposable multi-size Resonance ear tips
CRADLE
- For battery charging and desktop use
DATA
- Over 1,000 tests in the unit
- Internal database: Available and with possibility of reviewing test results
- Transfer to PC: via Bluetooth 2.1
STANDARD ACCESSORIES
- OAE Probe
- Medical Power supply
- MDS Software suite
- Disposable Ear Tips starter kit
- Calibration Cavity
- User’s Manual
- Carrying bag
- Pen Drive
- Touch screen pen
OPTIONALS
- Wi-Fi printer
- External keyboard
- USB Video otoscope
- Wallmount kit