MH PC-Based Spirometer
Modern PC-based spirometer offering maximum functionality and value.
- Easy Operation
- Short Test Time
- Automatic test results QC control
- Test results with high correlation compared with large PFT instrument
FEATURES:
- Conform to ATS and ERS standards.
- Standardised prediction value for different ethnic groups.
- Built-in bronchial dilation and provocation test modules.
- Vivid stimulation animation, good guide and introduction for small age patients.
- High precision differential pressure flow sensor combines with high efficiency filter can avoid cross
- contamination and give effective protection.
- More than 100 test parameters, fully meet the daily requirements and academic research requirements.
STANDARD CONFIGURATION:
| No. | Configuration | Quantity |
|---|---|---|
| 1 | USB Disk | 1 |
| 2 | Handle | 1 |
| 3 | Flow Sensor | 3 |
| 4 | Nose Clip | 1 |
| 5 | Spirometer User Manual | 1 |
| 6 | Warranty Card | 1 |
OPTIONAL CONFIGURATION:
- Bronchial provocation test mode
- External A4 printer connection mode
- Calibration syringe
INDICATIONS:
- COPD patients or borderline patients. PFT can detect COPD 5-10 years earlier than other methods such as X- ray, blood gas analysis and so on.
- Patients with bronchial asthma, emphysema, chronic bronchitis, pulmonary fibrosis and pneumoconiosis or tuberculosis, require diagnosis and efficacy evaluation.
- Patients with chronic cough.
- Patients with dyspnea or chest tightness.
- Long-term smoking or passive smokers.
- People under a polluted environment (live or work in a dusty environment).
- Patients require general anesthesia surgery, chest surgery and other surgeries (50 years above).
- Patients with symptoms such as cough or phlegm.
- Physical examination.
- Management of patients with bronchiectasis treatment.
- For damage determination and compensation inspection.
TECHNICAL DATA:
Measured parameters : > 100
- SVC: Test time SVC VC TV SVC IRV, ERV, IC, Ti SVC Te SVC, Ti/Te, FRC TLC, RV, RV/TLC IVC, EVC, Tfltot, Te/Ttot, Ttot SVC, RR SVC, TVffi, 60%VC
- FVC: Test time FVC, Exp time, FVC, FVC/Ht, FEVL FEVlo/oG, FEV1%t(ref), Inde-x, FEVI/Ht, PEF, MMEF, FEF90, FEF85, FEF75, FEF50, FEF25, FEFI0, FEF50/Ht, FEF25/Ht, FEFIO/Ht, FEF25/FEF10, FMFL OL, FEF50/FEF25, PEF/Ht, MTC75-50, MTC50-25, MTC25-RV, MTCR, MTCA, FEV0.5, FEV0.5%, Vextr%, Vextr- Ail (ref) , FIV0.5, FIVl, FIVl/FVC, PIF, CVI, FEV3, FEV3%G, FEV3%L FEV6, FEV6%, FVC+FEVl, FVCbest, FEVlbest, LUNG AGL FIVC, FIVI/FIVC- MEF200-1200, MEF25-50, MEF75-85, FIF25, FIF50, FIF75, FEV0.75, FEV0.75/FEV6, FEV0.75/FVC, FEV0.55 FEV0.6, FEV0.65, FEV0.7, FEV0.8, FEV0.85, FEV0.9, FEV0.95, FEV1/FEV6, FEF50/FIF50 (RS0) , FEVlNCpr, MET25-75, FEF50/FVC PEFR, FEV4, FEV5
- MVV: Test time MVV, MVV, MV/BSA, RR MVV, TV MVV, AVI(ref), MV C, MVV/(40*FEVl), Te MVV, Ti MVV, Ttot MVV
- MV: Test time MV, MV, RR MV, TV MV, VR, Te MV, TI MV, Ttot MV
- Sensor type: Differential pressure sensor
- Volume range : 0~16 L
- Flow range : 0~16L/s
- Volume accuracy : ±3% or 50 ml
- Flow accuracy : ±5% or 200 ml
- Airway resistance : <0.15 kPa/L/s
- PC communication : USB
- Bronchodilator test : Supported
- Bronchial challenge test : Supported
- Pediatric incentive : Supported